<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-27 07-21-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 5/5, 57 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.0 kHz -10 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
11 kHz 71 kHz 10060 0,0000
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
5,5 dBr 6,77 dBr 7,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 7:21, 27.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (57 dBuV) Max at: 71 kHz MIN: 11 kHz % above 76 kHz: 0,0000 Acquired: 2025/04/27 7:20:07 Total samples: 10060 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 7,7 dBr MIN: 5,5 dBr AVE: 6,77 dBr % above 10,2 dBr: 0,0 Last value: 7,6 dBr (2025/04/27 7:20:07) Station: 96.90 MHz, signal: 5/5 (57 dBuV) 07:13 07:14 07:15 07:16 07:17 07:18 07:19 07:20 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality